Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect

An Oracle White Paper

December 2006 Version 1.9

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect

1

Oracle RAC 10g Release 2 on Linux Cluster using RDS over IB Interconnect Installation and Configuration

INTRODUCTION

In Oracle Real Application Cluster (RAC) Technology, Cluster Interconnect is the key to maximizing its performance. RDS, Reliable Datagram Sockets protocol provides reliable datagram services multiplexing UDP packets over InfiniBand connection improving

performance to Oracle RAC. It provides high performance cluster interconnect for Oracle RAC 10g Release 2, utilizing InfiniBand which has 10X bandwidth advantage and 10X latency reduction vs. Gigabit Ethernet.

The reliable delivery capabilities inherent in InfiniBand that offload end-to-end error

checking to the InfiniBand fabric, freeing CPU cycles for application processing, thereby enabling processor scaling far greater than is possible with Ethernet.

The InfiniBand architecture delivers three levels of full duplex performance; the 1X link (2.5 gbit/s), the 4X link ( 10 gbit/s), and the 12X link (30 gbits/s)

IPoIB

Internet Protocol over InfiniBand (IPoIB) defines how Internet Protocol utilizes InfiniBand as a Link Layer protocol such as Ethernet. IPoIB provides significantly improved

bandwidth, latency, and reliability characteristics over Ethernet. The uses of IPoIB are entirely transparent to TCP/IP based applications, thereby providing system wide improvements.

Oracle uses IPOIB for CSS (node monitor) communication.

RDS

Reliable Datagram Sockets (RDS) is a reliable-socket off-load driver and inter-processor communication (IPC) protocol with low overhead, low-latency, high-bandwidth. RDS enables enhanced application performance and cluster scalability. RDS over InfiniBand uses approximately 50% less CPU per operation than IPoIB and operates with approximately half the latency of User Datagram Protocol (UDP) over Ethernet.

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect

2

Oracle uses RDS for cross instance database communication.

Advantages of IB/RDS as Interconnect Protocol in Oracle RAC 10g Release 2.

• • • • • •

High throughput gain over UDP Gigabit Ethernet (GIGE) Less latency of UDP GIGE and IPoIB Low CPU utilization

Easy to install and configure

Supports fail-over across Host Channel Adapter (HCA) ports and cards Stable deterministic performance under heavy CPU load

NETWORK CONFIGURATION FOR ORACLE CLUSTER

Component Specification Network

• eth0: Public network ( GIGE may be used )

• ib1: Infiniband network for Cluster Interconnect • Switch for Cluster Interconnect

o Configuration 1

One dual port IB Card with cable connected to port 1 and port 2 of HCA1

o Configuration 2

Two dual port IB Cards with cable connected to port 1 of each HCA1 and HCA2

• Oracle Clusterware 10.2.0.3

(This is the first Oracle version to support this new technology. At present this is only supported on Linux platform)

• Linux Kernel 2.6.9-34.Elsmp

• Oracle Clusterware and RAC 10.2.0.3 • SilverStorm RDS 3.3.0.10.1

• SilverStorm RDS 3.3.0.10.1

Clusterware

Software and patch level (Tested) Additional HA Software

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect

3

Configuration1 Configuration2

Figure 1.1 Network Configuration for Cluster

o Following diagram displays the configuration for cluster with two private

switches connected to DUAL port HCA to avoid single point of failure (SPOF)

o Both inter link switches (ISL) should be in one subnet to enable RDS failover

transparent to RAC

Figure 1.2 Network Configuration for cluster

(two private switches)

o Primarily we will explain about single switch configuration in this paper.

FABRIC HARDWARE INSTALLATION

• Install the High performance10Gbit/s, Full Bisectional Bandwidth (FBB) InfiniBand

switching fabric such as SilverStorm 9024 Switch that supports Ethernet and Fiber Channel.

• Connect one end of a Category 5 or 6 Ethernet cable to the RJ-45 connector on the

switch and the other end to the OOB LAN workstation.

• Install Host Channel Adapters (HCA) such as SilverStorm HCA 7000 in each server

in a 133MHZ PCI-X slot

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect

4

• Connect the switch to IB-enabled hosts using 4X-to-4X IB or IB/Fiber Optic cables.

Recommended distance limits for the IB/Fiber Optics is 100 meters • Power up the switch and monitor its boot process.

• The following are ways to determine that the system has started successfully:

o The IB link status indicator LEDs are lit up on the switch ports that are

connected to an IB host.

o The user is able to bring up Chassis Viewer through a web browser on the

OOB LAN.

o The homepage displays the 9024 switch ports

• There are three ways to view the boot process and configure the switch settings:

o From a terminal connect to the switch using ‘ssh’ as user admin

o Using the switch RS-232 port that is connected to a terminal, view or

configure the Switch settings with the following command line interface (CLI) from the terminal:

󰂃 Verify the system IP address:

󰂾 ShowChassisIpAddr

󰂃 Change the default IP address:

󰂾 setChassisIpAddr -h -m

󰂃 Change the default gateway IP address:

󰂾 setDefaultRoute -h

󰂃 Exit the CLI:

󰂾 logout

Example:

# ssh open

username-> admin password->

Welcome to the SilverStorm 9024 CLI. Type 'list' for the list of commands. -> showChassisIpAddr

Chassis IP Address: 10.35.58.21 Net mask: 255.255.252.0 ->

-> setChassisIpAddr -h 10.35.58.21 -m 255.255.255.0

You may need to reconnect if you have connected via: 10.35.58.21 OOB IP Address/netmask successfully updated ->

-> setDefaultRoute -h 10.35.58.21

You will have to reboot in order for the setting to take effect

o Using the Quicksilver Chassis Viewer GUI via web browser, using

http:// or http://

Chassis Viewer is browser based management software with the following management, configuration, monitoring and diagnostics functionality.

󰂃 Manage and view user-defined data 󰂃 Manage and monitor log files

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect

5

󰂃 Manage firmware updates

󰂃 Monitor component status and switch-level detailed information 󰂃 Configure the InfiniBand, Ethernet, and Fiber Channel features

Figure 2. Chassis Viewer

RDS SOFTWARE INSTALLATION

INSTALL OS PACKAGES

• Install the same recommended OS version for Oracle 10.2.0.3 on all hosts

• Master host i.e. the local host used for installing the software, should have full OS

installed including tcl and expect packages

# rpm –q tcl expect

• Configure each host to enable the master host to connect through ‘ssh’ or ‘rsh’.

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect

6

• For security reasons, it is highly recommended to configure ‘ssh’ in a production

environment. In case you use ‘rsh’ for installation, ensure that rsh, and rlogin are disabled after the installation is done

• On the master host, edit the “/etc/hosts” file and add all ethernet and IPoIB

addresses for all hosts and chassis in the fabric into it. Alternatively these addresses can be entered into DNS server and configure the hosts to access DNS server for name resolution.

Example:

# cat /etc/hosts

10.35.58.73 node1.example.com node1 10.35.58.74 node2.example.com node2 ........

10.35.58.114 node1-vip.example.com node1-vip 10.35.58.115 node2-vip.example.com node2-vip ........

192.128.96.45 node1-ib.example.com node1-ib 192.128.96.46 node2-ib.example.com node2-ib ........

INSTALL THE FABRIC ACCESS SOFTWARE ON THE MASTER HOST

• Download the latest release of InfiniServ 3.3.0.10.1 host access software from the

vendor website http://www.silverstorm.com/products/software.asp. ( It requires a license)

• Copy and extract the tar file ‘InfiniServ.3.3.0.10.1.tgz’ to the /root directory as root

user.

# cd /root ; tar -xvfz InfiniServ.3.3.0.10.1.tgz

• During installation, you will be asked for the following input:

o Number of IP over IB interfaces to configure o Interface names starting with ib1

o Base IPV4 address and netmask in dot notation for ib1

o Option for selecting between automatic or manual IPoIB configuration o Enable ib1 to autostart?

o Select HCAs to update firmware version

NOTE: 2-port redundant configuration is default for automatic option.

• Start the installation:

# cd /root/InfiniServ.3.3.0.10.1 ;

# ./INSTALL ? -- for help and install options

# ./INSTALL

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect

7

First select the “Install/Uninstall Software” option and then select the “Perform the selected actions” option to install all the drivers.

• Upon completion of the installation, remove the stage directory • Create the following files:

/etc/sysconfig/iba/hosts -- listing the Ethernet hostname of all hosts in the

cluster except the master node

/etc/sysconfig/iba/allhosts -listing the Ethernet hostnames including the

master node

/etc/sysconfig/iba/chassis -- edit it to add all the chassis Ethernet names (ip_addr.)

Examples:

# cat /etc/sysconfig/iba/hosts

node1-ib node2-ib node3-ib ………

# cat /etc/sysconfig/iba/allhosts

node1 node2 node3 ………

# cat /etc/sysconfig/iba/chassis

I9024

10.35.58.21

• Review the Fast Fabric configuration file “/etc/sysconfig/fastfabric.conf”

Example:

# cat /etc/sysconfig/fastfabric.conf

if [ \"$CONFIG_DIR\" = \"\" ] then

if [ -d /etc/sysconfig ] then

CONFIG_DIR=/etc/sysconfig else

CONFIG_DIR=/etc fi

export CONFIG_DIR fi

export HOSTS_FILE=\"${HOSTS_FILE:-$CONFIG_DIR/iba/hosts}\"

export CHASSIS_FILE=\"${CHASSIS_FILE:-$CONFIG_DIR/iba/chassis}\" export FF_IPOIB_SUFFIX=\"${FF_IPOIB_SUFFIX:--ib}\" export MGMT_HOST=\"${MGMT_HOST:-localhost}\" ……. …….

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect

8

• Reboot the master host

• Run the Fast Fabric ToolSet User interface (TUI) ‘iba_config’ menu system to update

the firmware and to verify connectivity with the switch

# /sbin/iba_config

Select the “Chassis Admin via Fast Fabric” option, then select the following options:

Verify Chassis via Ethernet ping *(# pingall –C –p)

Update Chassis Firmware (# ibtest –C -a run –P upgrade) Reboot Chassis (# ibtest – C reboot)

NOTE: The Chassis Viewer GUI can be used to update firmware individually

*Equivalent command line interface to carry out the specific task

INSTALL THE FABRIC ACCESS SOFTWARE ON REMAINING HOSTS IN THE CLUSTER

• Run the Fast Fabric ToolSet User interface (TUI) ‘/sbin/iba_config’ menu system for

installing the software in other hosts. After IPoIB is installed, configure the ifcfg-ib1 interface on each host to use the IPoIB address found in /etc/hosts (or via DNS) on each given host. Reboot all servers. Refresh the known hosts and ssh keys so the IPoIB addresses are included.

# /sbin/iba_config

Select the “Host Setup via Fast Fabric” option and then select the following options:

Verify the hosts are accessible via the Ethernet network *(# pingall –p) Verify rsh setup (# check_rsh –I) Configure ssh (# setup_ssh –I) Replicate /etc/hosts file in all hosts (# scpall –p /etc/hosts) Review host OS versions (# uname –a) Select Install/Upgrade InfiniServ Software (# ibtest load) Select Configure IPoIB IP Address (# ibtest configipoib) Reboot all hosts (# ibtest reboot) Refresh ssh Known Hosts (# setup_ssh –C)

* Equivalent command line interface to carry out the specific task

VERIFY FABRIC HARDWARE CONNECTIVITY

• Run the Fast Fabric ToolSet User interface (TUI) ‘iba_config’ menu system to verify

connectivity:

# /sbin/iba_config

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect

9

• Select the “Chassis Admin via Fast Fabric” menu item and then select the following

option to verify integrity of all ports

Show Status of Chassis IB ports (# showallports –C)

• Select the “Host Admin via Fast Fabric” menu item and then select the following

options to verify the fabric configuration, integrity of all ports, that all hosts can see each other via the subnet agent (SA) and have fully populated their SA cache and the master host can ping other hosts via IPoIB

See Summary of Fabric Components (# fabric_info) Show Status of Host IB ports (# showallports) Verify Hosts see each other (# ibtest sacache) Verify Hosts ping via IPoIB (# ibtest ipoibping)

NOTE: Review the output of ‘showallports’ command to ensure no links have excessive symbol errors (i.e., more than 200). For excessive symbol errors look for any configuration or network hardware issues.

ORACLE CLUSTERWARE AND RAC10gR2 INSTALLATION

• Using Cluster Verification Utility, verify the prerequisites for the CRS installation:

# cluvfy stage -pre crsinst -n

NOTE: You can find the utility on the Oracle Clusterware installation media.

• Apply all OS patches for the Linux 2.6.9-34.Elsmp Kernel as recommended in the

Oracle 10gR2 Installation manual

# rpm –ivh .rpm

• Edit the file “/etc/sysctl.conf” and set the value for shared memory, semaphore,

message, network buffer and data buffer the kernel parameters as recommended in the Oracle 10gR2 Installation manual.

• Confirm IPoIB network is configured properly (Refer to the “Verify Fabric Hardware

connectivity” Section above)

• Verify current IPoIB /RDS failover configuration. The default configuration is for Dual

port HCA. For Multiple HCA, edit the “ipoib.cfg” file as follows:

o For RDS fail-over between ports of a single HCA, cable both HCA ports to the

InfiniBand fabric and configure IPoIB editing “/etc/sysconfig/ipoib.cfg” file with primary and secondary ports, either by referencing port numbers or GUIDs as follows:

{

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect

10

CREATE; NAME=\"ib1\";

PRIMARY ={PORT=1 | PORTGUID=0x66A00b1000101;} SECONDARY={PORT=2 | PORTGUID=0x66A01b1000101;}}

o For RDS fail-over between two HCAs in a server, configure IPoIB editing

“/etc/sysconfig/ipoib.cfg” file, referencing port GUIDs for port 1 of each HCA as follows:

{

CREATE; NAME=\"ib1\";

PRIMARY ={PORTGUID=0x66A00b1000101;} SECONDARY={PORTGUID=0x67200b1000101;}}

• Install Oracle Clusterware software 10.2.0.1 in either local or shared CRS_HOME,

depending upon your current architecture

NOTE: Upgrade the software to 10.2.0.3 minimum before creating the database.

• Configure OCR Disks and mirrored Voting disks

o OCR Disks with two partitions /dev/raw/raw1 and /dev/raw/raw2, each of size

200MB.

o Voting Disks with three partitions /dev/raw/raw3, /dev/raw/raw4 and

/dev/raw/raw5, each of size 200MB with normal redundancy

• Configure ASM with available block device.

• Configure network with three IP addresses for:

o Public network interface (GIGE may be used) o IB for Cluster Interconnect o Virtual IP address

Examples:

# cat /etc/hosts

10.35.58.73 node1.example.com node1 10.35.58.114 node1-vip.example.com node1-vip 192.128.96.45 node1-ib.example.com node1-ib

…………………………

…………………………….

• Install Oracle 10.2.0.1 RDBMS software and upgrade the software to 10.2.0.3 before

creating the database. Clusterware and RDBMS version has to be 10.2.0.3 to relink Oracle successfully with RDS.

• Create the database using ASM storage

• Configure RAC to utilize Infiniband and RDS after creating the database

o To configure RAC over RDS,

󰂃 First validate the Oracle RAC operation over IPoIB

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect

11

󰂃 Shut down all Oracle instances

󰂃 Build the RAC IPC library for RDS (i.e. relink Oracle binary with RDS)

by performing the following as oracle user

$ cd $ORACLE_HOME/rdbms/lib

$ make -f ins_rdbms.mk ipc_rds ioracle

󰂃 Restart Oracle instances

NOTE: For non-shared ORACLE_HOME, the above commands must be run on each node of the RAC cluster.

• For existing Oracle installations, to configure the cluster interconnect with RDS,

change the cluster interconnect interface on each node using the Oracle Interface Configuration Tool (oifcfg), as follows:

o Shutdown all Oracle instances

o Using “oifcfg”, change the cluster interconnect to InfiniBand IP address

$ oifcfg getif –global

$ oifcfg delif –global

$ oifcfg setif –global ib1/192.128.96.0:cluster_interconnect

NOTE: oifcfg requires CRS to be running.

o Stop the CRS stack as root with “crsctl stop crs” on all nodes

o Modify the /etc/hosts file on each node to map the new IP address with the

existing private hostname.

o Start the CRS stack as root with “crsctl start crs” on all nodes o Restart all Oracle instances.

o RAC will now utilize InfiniBand with UDP IPC traffic passed using IPoIB for

CSS communication

Confirm IPoIB use via IPoIB interface statistics or by checking SilverStorm switch port statistics via switch GUI.

o Relink the Oracle binary to use the RDS as stated above. Verify this by

searching for the “cluster interconnect IPC version:Oracle RDS/IP (generic) “ line in the alert log file

CAUTION: Shutting down the previously used network interface or by removing the old Network Interface Card used for cluster interconnect may cause the node to reboot. To prevent this to occur, ensure that the new IP address is being used for cluster interconnect at both the Database and CSS level. Use the following commands to verify:

$ egrep `olsnodes -p -l|awk ' { print $2 } '` /etc/hosts; $oifcfg getif -global|egrep interconnect|awk ' { print $2 }'

Both commands should return the same subnet and make sure the displayed hostname is the correct private hostname.

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect

12

• To revert back RAC to UDP, shut down all Oracle instances, log in as Oracle user

and execute the following on each node of the cluster:

$ cd $ORACLE_HOME/rdbms/lib

$ make -f ins_rdbms.mk ipc_g ioracle

Also, update /etc/hosts and run oifcfg as required to restore the desired cluster interconnect, per instructions above.

RDS over IB MANUAL CONFIGURATION

MODIFY IPoIB CONFIGURATION

• IP over IB requires the configuration file “/etc/sysconfig/ipoib.cfg” to specify

parameters for each IP over IB device. The default configuration file provides for a 2 port redundant configuration. If you desire a different configuration for IP over IB, manually edit the file as mentioned below:

o Edit the configuration file, “/etc/sysconfig/ipoib.cfg”, add a CREATE block to

the file in the following format:

Example:

#cat /etc/sysconfig/ipoib.cfg

{CREATE; NAME=\"ib1\"; PORTGUID=\"0x00066a00b1000101;}

For each CREATE block (IP Link Layer interface) defined in the

“/etc/sysconfig/ipoib.cfg” file, create an interface configuration file, “/etc/sysconfig/network-scripts/ifcfg-.”.

Example:

DEVICE=ib1

BOOTPROTO=static IPADDR=192.128.96.45 NETMASK=255.255.252.0 ONBOOT=yes

#cat /etc/sysconfig/network-scripts/ifcfg-ib1

o (Re)start the IpoIB driver # /etc/init.d/ipoib restart

or

Start IpoIB #iba_start ipob

o To reconfigure IPoIB, you can use 'iba_config' text user interface command as stated in the above section.

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect

13

MODIFY RDS CONFIGURATION

• Readonly parameters can only be set at driver load, in order to do so, edit the file

/etc/modprobe.conf, add parameter=value in the options RDS line.

Example:

# cat /etc/modprobe.conf

options rds MaxDataSendBuffers=200

and then restart RDS or reboot.

• To change a runtime configurable parameter, write the parameter to the

‘/poc/driver/rds/config’ file

Example:

# echo “ Heartbeat =0” > /proc/driver/rds/config

CONFIGURE “rdsping” SERVER MANUALLY

• Start ‘rdsping’ server to verify RDS connectivity between nodes in a RAC cluster.

• Start the server side of rdsping as follows:

# /sbin/rdsping –d

• Once server side rdsping process is running, ping via RDS as follows:

# /sbin/rdsping [-n num]

-- where resolves to the IPoIB IP address

• For “rdsping” server to start automatically upon node reboot:

# echo /sbin/rdsping –d >/etc/rc.d/rc3.d/S97rdsping # chmod 755 /etc/rc.d/rc3.d/S97rdsping

RDS SETUP VERIFICATION

Verify RDS configuration/setup and Cluster Interconnect network and protocol settings by following UNIX commands and SQL statements:

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect

14

• Verify the PCI IB card model

# lspci –vv --look for “InfiniBand” section

Example:

InfiniBand: Mellanox Technologies MT23108 InfiniHost (rev a1) Subsystem: Mellanox Technologies MT23108 InfiniHost

Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV+ VGASnoop- ParErr- Stepping- SERR+ FastB2B

Status: Cap+ 66Mhz+ UDF- FastB2B- ParErr- DEVSEL=medium >TAbort- SERR- Latency: , Cache Line Size 10 Interrupt: pin A routed to IRQ 66

Region 0: Memory at df300000 (-bit, non-prefetchable) [size=1M] Region 2: Memory at d7800000 (-bit, prefetchable) [size=8M] Region 4: Memory at c8000000 (-bit, prefetchable) [size=128M] Capabilities:

• Verify if IB Driver is installed

# modinfo –d ics_dsc

Example:

SilverStorm Technologies Inc. IB Discovery Driver, version 3.3.0.10.1

• Verify if RDS is configured

# /sbin/chkconfig –list|grep rds

Example:

rds 0:off 1:off 2:off 3:on 4:off 5:on 6:off

• Verify HCA driver modules ( ipoib and rds)

# ls /lib/modules/2.6.9-34.ELsmp/iba ipoib.ko rds.ko

• Verify that the HCA drivers are running:

# /sbin/lsmod|egrep rds # /sbin/lsmod|egrep ib

Example:

# /sbin/lsmod|egrep rds ; /sbin/lsmod|egrep ib

rds 94796 96 ics_offload 11040 2 rds ipoib 122588 1 rds ics_dsc 74092 3 rds,ipoib,ics_srp ibt 714628 8 rds,ics_offload,ipoib,ics_srp,ics_dsc,mt23108vpd libcrc32c 6721 1 crc32c

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters

Using RDS over InfiniBand Interconnect

15

ipoib 122588 1 rds

ics_dsc 74092 3 rds,ipoib,ics_srp

ibt 714628 8 rds,ics_offload,ipoib,ics_srp,ics_dsc,mt23108vpd

• Findout the IP address of HCAs in a node

# /sbin/ipoib_path

Example:

Name: node1 Addr: 10.35.58.73 1 Paths: Path: 0

DGID: 0xfe70000000000000:0002c9020021ecb9 DLID: 8

SGID: 0xfe70000000000000:0002c9020021ecb9 SLID: 8 SL: 0

PKey: 0xffff Mtu: 2048 Rate: 10g Life: 134 ms

• Verify status of IB port1 and port2

# /sbin/p1info # /sbin/p2info

Example:

Port 1 Info

PortState: Active PhysState: LinkUp DownDefault: Polling LID: 0x0008 LMC: 0

Subnet: 0xfe80000000000000 GUID: 0x0002c9020021ecb9

SMLID: 0x0001 SMSL: 0 RespTimeout : 33 ms SubnetTimeout: 536 ms M_KEY: 0x0000000000000000 Lease: 0 s Protect: Readonly MTU: Active: 2048 Supported: 2048 VL Stall: 0

LinkWidth: Active: 4x Supported: 1-4x Enabled: 1-4x

LinkSpeed: Active: 2.5Gb Supported: 2.5Gb Enabled: 2.5Gb VLs: Active: 4+1 Supported: 4+1 HOQLife: 4096 ns Capability 0x02010048: CR CM SL Trap

Violations: M_Key: 0 P_Key: 0 Q_Key: 0

ErrorLimits: Overrun: 15 LocalPhys: 15 DiagCode: 0x0000 P_Key Enforcement: In: Off Out: Off FilterRaw: In: Off Out: Off

• Verify RDS Version and value of tunable parameters

# cat /proc/driver/rds/config

Example:

rds version 3.3.0.10.1

for SilverStorm Technologies Inc. Infiniband(tm) Rds , version 3.3.0.10.1 Built for Linux Kernel 2.6.9-34.ELsmp

RdsDbgLvl - Logging for Rds

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect

16

Bit masks are as follows:

0x80000000 - Serious Errors 0x40000000 - Errors

0x20000000 - Warnings

0x10000000 - Informational messages

RdsTraceLvl - Time tracing for Rds

Bit masks are as follows: 0x00000000 - Trace All

0x00001000 - Trace Sends 0x00002000 - Trace Recvs 0x00004000 - Trace Poll 0x00008000 - Trace Ctrl

Parameter Values:

RdsDbgLvl=0xc0000000 RdsTraceLvl=0x00000000 =MinRnrTimer=10 PerfCounters=1

PendingRxPktsHWM=75 -- Pending Rx buffers High Water Mark (percentage) =Heartbeat=0 - Heartbeat ON/OFF SessionCloseTimeWait5000 - SessionCloseTimeWait (milliseconds)

Read Only Parameters (set at module load time):

UserBufferSize4096 - User buffer size MaxDataRecvBuffers=500 - Max data recv buffers MaxDataSendBuffers=100 - Max data send buffers MaxCtrlRecvBuffers=100 - Max ctrl recv buffers MaxCtrlSendBuffers=50 - Max ctrl send buffers DataRecvCoalesceFactor=10 - Max Recv buffer coalescing (percentage) DataRecvBufferLVM=50 - Recv buffer Low Water Mark (percentage) MaxRecvMemory=32000 - Performance Counters ON/OFF

• Verify IB Interface Configuration

# ifconfig –ib1

Example:

ib1 Link encap:Ethernet HWaddr 26:02:C9:21:CC:B9

inet addr:192.128.96.45 Bcast:192.128.96.255 Mask:255.255.255.0 inet6 addr: fe80::2402:c9ff:fe21:ccb9/ Scope:Link

UP BROADCAST RUNNING MULTICAST MTU:2044 Metric:1 RX packets:8143830 errors:0 dropped:0 overruns:0 frame:0 TX packets:8061004 errors:0 dropped:2 overruns:0 carrier:0 collisions:0 txqueuelen:1000

RX bytes:1524279209 (1.4 GiB) TX bytes:993291326 (947.2 MiB)

• List Network Interface configuration

# oifcfg iflist

Example:

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect

17

eth0 10.35.58.0 eth1 10.35.44.0 ib1 192.128.96.0

• Get the subnet and interface for public / private network

# oifcfg getif

Example:

eth0 10.35.58.0 global public

ib1 192.128.96.0 global cluster_interconnect

• View active cluster nodes from master node

# cat /etc/sysconfig/iba/hosts

Example:

node1-ib node2-ib node3-ib node4-ib node5-ib …………. ………….

• Verify if the node is accessible via RDS

# /sbin/rdsping

Example:

rdsping node5-ib

RDS-PING (node5-ib) bytes of data.

recvd bytes from node5-ib: time = 24.050000 usec recvd bytes from node5-ib: time = 23.950000 usec recvd bytes from node5-ib: time = 26.100000 usec

• Verify private hostname used for cluster_interconnect

# olsnodes –p –l

Example:

node5 node5-ib

• Verify which interface being used for cluster_interconnect

# ocrdump ;egrep ib1 OCRDUMPFILE

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect

18

Example:

[SYSTEM.css.interfaces.global.ib1]

[SYSTEM.css.interfaces.global.ib1.192|d128|d96|d0] [SYSTEM.css.interfaces.global.ib1.192|d128|d96|d0.1]

• Verify that the IB and RDS Drivers started up successfully during node startup

# cat /var/log/messages # cat /var/log/boot.log # dmesg

Example:

SilverStorm Technologies Inc. InfiniBand(tm) Transport Driver, version 3.3.0.10.1 Copyright (C) 2000-2002 InfiniCon Systems(r)

Copyright (C) 2005 SilverStorm Technologies Inc. Copyright (C) 2000-2001 Intel Corporation Built for Linux Kernel 2.6.9-34.ELsmp

mt23108vpd: no version for \"SpinRwLockInit\" found: kernel tainted.

Initializing SilverStorm Technologies Inc. MT23108/MT25208 Verbs Provider Driver, version 3.3.0.10.1

for SilverStorm Technologies Inc. Infiniband(tm) Transport Driver, version 3.3.0.10.1 Built for Linux Kernel 2.6.9-34.ELsmp

Adding CA (vendor=0x15b3, device=0x5a44) CR space at 0xdf300000 1 MB (0x100000 Bytes) UAR space at 0xd7800000 8 MB (0x800000 Bytes)

HCA DDR memory at 0xc8000000 128 MB (0x8000000 Bytes)

ACPI: PCI interrupt 0000:0b:00.0[A] -> GSI 101 (level, low) -> IRQ 66 Interrupt pin 1 routed to IRQ 66

Set PCI Max Read Byte Count (at 0x70) to 4096 bytes

Set PCI Max Outstanding Split Transactions (at 0x70) to 2 InfiniServ HCA 1, Firmware version: 3.3.5 FW: 6291456 bytes

QPC/EQPC: 65536 QPs 18874368 bytes RDB: 4 RDMA Resp 8388608 bytes CQ: 16384 CQs 1048576 bytes

MPT: 524288 MPTs (131072 MRs, 262144 MWs) 3332 bytes MTT: 4194304 entries (8 per seg) 3332 bytes UAR Scratch: 2048 UARs 65536 bytes EQC: EQs 4096 bytes

MCG: 8192 MCGs 524288 bytes AV: 995200 AVs 318400 bytes

Cmds: DB: 1 Max Outstanding: , Max In Mbx: 1024 bytes, Max Out Mbx: 1024 bytes Cmd Timeout: A: 5000000 usec, B: 10000000 usec, C: 20000000 usec, D: 50000000 usec Node Guid: 0x0002d9020421ceb5 Port 1 Guid: 0x0002d9020421ceb96 Port 2 Guid: 0x0002d9020421cebc

ICS DSC:Initializing SilverStorm Technologies Inc. IB Discovery Driver, version 3.3.0.10.1 ICS DSC:Built for Linux Kernel 2.6.9-34.ELsmp ICS DSC:Found 1 HCAs

ICS SRP:Initializing SilverStorm Technologies Inc. Virtual HBA (SRP) SCSI Driver, version 3.3.0.10.1

ICS SRP:Built for Linux Kernel 2.6.9-34.ELsmp ICS SRP:Using Physical memory model. ICS SRP:Found 1 HCAs

IPOIB: Initializing SilverStorm Technologies Inc. IP over IB Driver, version 3.3.0.10.1 IPOIB: Built for Linux Kernel 2.6.9-34.ELsmp divert: allocating divert_blk for ib1

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect

19

Initializing ics_offload version 3.3.0.10.1

for SilverStorm Technologies Inc. Infiniband(tm) Transport Driver, version 3.3.0.10.1 Built for Linux Kernel 2.6.9-34.ELsmp NET: Registered protocol family 30 Initializing rds version 3.3.0.10.1

for SilverStorm Technologies Inc. Infiniband(tm) Rds , version 3.3.0.10.1 Built for Linux Kernel 2.6.9-34.ELsmp RDS:Found 1 HCAs

RDS: ops_proto_register success!!

ip_tables: (C) 2000-2002 Netfilter core team

IB Port State Change: Hca 1 Port 1 New State: Active PhysState: LinkUp IPOIB: ib1: Using Primary path

• Verify that RAC is using desired IPC protocols from alert.log file

Check for the string “cluster interconnect IPC version:Oracle RDS/IP (generic)” in the alert.log file.

Example:

………… …………

Starting ORACLE instance (normal) LICENSE_MAX_SESSION = 0

LICENSE_SESSIONS_WARNING = 0

Interface type 1 ib1 192.128.96.0 configured from OCR for use as a cluster interconnect Interface type 1 eth0 10.35.58.0 configured from OCR for use as a public interface ………………………….

SYS auditing is disabled

ksdpec: called for event 13740 prior to event group initialization Starting up ORACLE RDBMS Version: 10.2.0.3.0. …………………… …………………….

pga_aggregate_target = 387973120

Cluster communication is configured to use the following interface(s) for this instance 192.128.96.46

Mon Oct 23 11:31:07 2006

cluster interconnect IPC version:Oracle RDS/IP (generic) IPC Vendor 1 proto 3 Version 1.0

PMON started with pid=2, OS id=18765 DIAG started with pid=3, OS id=18796 ……………………..

• Verify that the correct network is used for database cluster interconnect

SQL> SELECT INST_ID, NAME, IP_ADDRESS, IS_PUBLIC, SOURCE

FROM GV$CLUSTER_INTERCONNECTS ORDER BY INST_ID;

Example:

INST_ID NAME IP_ADDRESS IS_PUBLIC SOURCE

---------- --------------- ---------------- --- ---------------------------------------------------------- 2 ib1 192.128.96.45 NO Oracle Cluster Repository 4 ib1 192.128.96.46 NO Oracle Cluster Repository 5 ib1 192.128.96.47 NO Oracle Cluster Repository

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters

Using RDS over InfiniBand Interconnect

20

………………………………………. ……………………………………….

or use oradebug like below

SQL> oradebug setmypid SQL> oradebug ipc

SQL> oradebug tracefile_name

Example:

# cat /home/ractest/oracle/OraHome/admin/RAC/udump/rac7_ora_30741.trc

…………………..

wait delta 333 sec (333729 msec) ctx ts 0x85807 last ts 0x34194 user cpu time since last wait -171798692 sec 42949672 ticks system cpu time since last wait -1 sec 0 ticks locked 1 blocked 0

timed wait receives 0

admno 0x3c7ecb0f admport:

SSKGXPT 0xcd8c160 flags socket no 7 IP 192.128.96.46 RDS 63065 context timestamp 0x85807 no ports

sconno accono ertt state seq# sent async sync rtrans acks 0x043afd78 0x15cfefe8 3 327 1 1 0 0 0 0x043afd79 0x4a030532 3 32771 8 8 0 0 0 …………………………….

SQL> SELECT INST_ID, PUB_KSXPIA, PICKED_KSXPIA, NAME_KSXPIA,

IP_KSXPIA FROM X$KSXPIA ORDER BY INST_ID;

Example:

INST_ID ---------- 2 2

PUB_KSXPIA PICKED_KSXPIA NAME_KSXPIA IP_KSXPIA ---------- ------------------------ ------------------------- ---------------- Y OCR eth0 10.35.58.74 N OCR ib1 192.128.96.46

RDS PERFORMANCE MONITORING

Monitor RDS statistics using the following OS commands:

• When RDS is running, an associated directory structure will be present in the /proc

file system ( /proc/driver/rds )

• Start ‘/sbin/iba_mon’ as a daemon on all the nodes with values set in the

“iba_mon.conf. “ configuration file.

# cat /etc/sysconfig/iba/iba_mon.conf # /sbin/iba_mon –d

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect

21

Example:

# cat /etc/sysconfig/iba/iba_mon.conf Interval 10 # monitoring interval in seconds SyslogFacility local6 # syslog facility code, or disable PortXmitData 0 # as MB/second PortRcvData 0 # as MB/second PortXmitPkts 0 # as packets/second PortRcvPkts 0 # as packets/second SymbolErrorCounter 100 LinkErrorRecoveryCounter 3 LinkDownedCounter 3 PortRcvErrors 100 PortRcvRemotePhysicalErrors 100 PortRcvSwitchRelayErrors 100 PortXmitDiscards 100 PortXmitConstraintErrors 10 PortRcvConstraintErrors 10 LocalLinkIntegrityErrors 3 ExcessiveBufferOverrunErrors 3 VL15Dropped 100

# /sbin/iba_mon -d

iba_mon: Starting iba_mon: Settings:

iba_mon: Interval 10 iba_mon: SyslogFacility local6 iba_mon: SymbolErrorCounter 100 iba_mon: LinkErrorRecoveryCounter 3 iba_mon: LinkDownedCounter 3 iba_mon: PortRcvErrors 100 iba_mon: PortRcvRemotePhysicalErrors 100 iba_mon: PortRcvSwitchRelayErrors 100 iba_mon: PortXmitDiscards 100 iba_mon: PortXmitConstraintErrors 10 iba_mon: PortRcvConstraintErrors 10 iba_mon: LocalLinkIntegrityErrors 3 iba_mon: ExcessiveBufferOverrunErrors 3 iba_mon: VL15Dropped 100

[root@node1]# iba_mon: Port 0x0002c9020021ccb9 Active iba_mon: Port 0x0002c9020021ccba Down

• To Monitor RDS usage statistics

# cat /proc/driver/rds/stats

Example:

# cat /proc/driver/rds/stats Rds Statistics:

Sockets open: 96 End Nodes connected: 14

Performance Counters: ON Transmit:

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect

22

Xmit bytes 13531877 Xmit packets 3417817 Xmit errors 3 Loopback packets dropped 0

Receive:

Recv bytes 1265875795 Recv packets 3401421 Recv packets pending 0 Recv packets dropped 278 Recv errors 5814

Stalled Ports: 0 Stalls Sent 0 Unstalls Sent 0 Stalls Recvd 0 Unstalls Recvd 0

Debug Stats:

ENOBUFs (105) returned 0

EWOULDBLOCKs(11) returned 71 Rx pkts pending HWM 5607 Rx pkts coalescing 50 Rx buf alloc failed 0 Rx post_thread_wakeups 0 Stall events ignored 0 Session failovers 3

• To view RDS connections in use

# cat /proc/driver/rds/info

Example:

# cat /proc/driver/rds/info Session Info:

IP State Rx bufs Rx Cache 192.128.96.45 ACTIVE 499 0 192.128.96.46 ACTIVE 468 0 …………. ………….

192.168.100.51 ACTIVE 4 0 192.168.100.16 IDLE 0 0 --------------------- Socket Info:

Port Rx pending State

• View IB network statistics and monitor cluster interconnect for any collisions, errors

and lost packets on the ib Interface

# /bin/netstat –i

Example:

# netstat -i

Kernel Interface table

Iface MTU Met RX-OK RX-ERR RX-DRP RX-OVR TX-OK TX-ERR TX-DRP TX-OVR Flg eth0 1500 0 1127673 0 0 0 711366 0 0 0 BMRU

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect

23

eth0:1 1500 0 - no statistics available - BMRU eth1 1500 0 829395 2 0 0 331282 0 0 0 BMRU ib1 2044 0 10020829 0 0 0 98208 0 2 0 BMRU lo 136 0 3991905 0 0 0 3991905 0 0 0 LRU

• Measure Interconnect Traffic

# /usr/bin/sar –n DEV

Example:

# /usr/bin/sar -n DEV|more

Linux 2.6.9-34.ELsmp (node1) 11/30/2006

10:10:01 PM IFACE rxpck/s txpck/s rxbyt/s txbyt/s rxcmp/s txcmp/s rxmcst/s 10:10:01 AM ib1 29.53 28.86 5092.14 3393.59 0.00 0.00 0.07 10:20:01 AM ib1 29.49 28.46 5101.32 3373.69 0.00 0.00 0.06 10:30:01 AM ib1 29.45 28.35 5086.49 33.08 0.00 0.00 0.06 10:40:01 AM ib1 29.49 28.18 5100. 3357.71 0.00 0.00 0.07 10:50:01 AM ib1 29.45 28.35 5075.19 3360.91 0.00 0.00 0.06 11:00:01 AM ib1 29.42 28.22 5077.42 3355.07 0.00 0.00 0.06 11:10:01 AM ib1 29.46 28.23 5099.52 3360.73 0.00 0.00 0.07 11:20:01 AM ib1 29.48 28.24 5100. 3361.19 0.00 0.00 0.06 11:30:01 AM ib1 29.43 28.18 5085.15 33.46 0.00 0.00 0.06 11:40:01 AM ib1 29.43 28.27 5084. 3358.86 0.00 0.00 0.07 Average: ib1 30.32 29.70 7218.50 4601.99 0.00 0.00 0.06

• Get the IB port1 and port2 statistics

# /sbin/p1stats # /sbin/p2stats

# /sbin/showallports –h ‘

Example:

Port 1 Counters

Performance: Transmit

Xmit Data 3039 MB (7968598 Quads) Xmit Pkts 17023482 Performance: Receive

Rcv Data 3627 MB (9509127 Quads) Rcv Pkts 17092369

Errors: Async Events:

Symbol Errors 0 State Change 0 Link Error Recovery 0 Traps:

Link Downed 0 Link Integrity 0 Port Rcv Errors 0 Exc. Buffer Overrun 0 Port Rcv Rmt Phys Err 0 Flow Control Watchdog 0 Port Rcv Sw Relay Err 0 Capability Mask Chg 0 Port Xmit Discards 0 Platform Guid Chg 0 Port Xmit Constraint 0 Bad M-Key 0 Port Rcv Constraint 0 Bad P-Key 0 Local Link Integrity 0 Bad Q-Key 0 Exc. Buffer Overrun 0 Other 0 VL15 Dropped 0

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect

24

• Clear the IB Port Statistic history

# /sbin/clear_p1stats # /sbin/clear_p2stats

• View HCA and Port level statistics from “/proc/iba/mt23108/” location

• View memory usage by RDS

# cat /proc/slabinfo |grep RDS; cat /proc/slabinfo|grep IPOIB

Example:

RDS:control 2200 2205 256 15 1 : tunables 120 60 8 : slabdata 147 147 0 RDS:data 8105 8105 4352 1 2 : tunables 8 4 0 : slabdata 8105 8105 0 IPOIB:ports 14 135 28 135 1 : tunables 120 60 8 : slabdata 1 1 0 IPOIB:mac 14 65 60 65 1 : tunables 120 60 8 : slabdata 1 1 0 IPOIB:av 19 214 36 107 1 : tunables 120 60 8 : slabdata 2 2 0

• View IB Card or Port failover log

# cat /proc/iba/log

Example:

………………………… ……………………………

0004294697: IPOIB: Initializing SilverStorm Technologies Inc. IP over IB Driver, version 3.3.0.10.1

0004294697: IPOIB: Built for Linux Kernel 2.6.9-34.ELsmp 0004294697: Initializing rds version 3.3.0.10.1

for SilverStorm Technologies Inc. Infiniband(tm) Rds , version 3.3.0.10.1 0004294697: Built for Linux Kernel 2.6.9-34.ELsmp 0004294697: RDS:Found 1 HCAs

0004294697: IB Port State Change: Hca 1 Port 1 New State: Active PhysState: LinkUp 0004294697: IPOIB: ib1: Using Primary path

………………………………… ………………………………

• Measure the RDS traffic throughput finding the packet counts in the

“/proc/driver/rds/stats” file

• From AWR / statspack report, monitor the “global_cache_statistics” wait events

Example:

INST_ID NAME VALUE

-------------------- --------------------------------------------- --------------------

2 gc cr blocks served 234 2 gc cr block build time 36 2 gc cr block flush time 1676 2 gc cr block send time 63 2 gc current blocks served 110207 2 gc current block pin time 58 2 gc current block flush time 104

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect

25

2 gc current block send time 346

2 gc cr blocks received 11082

2 gc cr block receive time 703

2 gc current blocks received 30782

2 gc current block receive time 1384 2 gc local grants 13624 2 gc remote grants 99393 2 gc blocks lost 0 2 gc claim blocks lost 0 2 gc blocks corrupt 0 2 gc CPU used by this session 93

• Verify that instances are running:

o SQL> SELECT * FROM V$ACTIVE_INSTANCES; Example:

INST_NUMBER INST_NAME

-------------------- ------------------------------------------------------------ 2 node1: rac1 4 node2: rac2 5 node3: rac3

… .…………….. … ………………

o SQL> SELECT INSTANCE_NAME, HOST_NAME, VERSION,

STARTUP_TIME, STATUS, LOGINS, DATABASE_STATUS, BLOCKED FROM GV$INSTANCE;

Example:

INSTANCE_NAME HOST_NAME VERSION STARTUP_T STATUS LOGINS DATABASE_STATUS BLO

---------------- ---------- ----------------- --------- ------------ ---------- ----------------- ---

rac1 node1 10.2.0.3.0 28-NOV-06 OPEN ALLOWED ACTIVE NO rac2 node2 10.2.0.3.0 28-NOV-06 OPEN ALLOWED ACTIVE NO rac3 node3 10.2.0.3.0 28-NOV-06 OPEN ALLOWED ACTIVE NO …….. ….….. …………. …………………. ……...……. .……….. …. …….. ….….. …………. …………………. ……...……. .……….. ….

DIAGNOSIS

In case of node hung or crash, for debugging purpose,

• Enable the magic keys at OS level:

# sysctl –w kernel.sysrq=1

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect

26

• Enable and start the NMI watchdog timer on nodes to capture the stack by setting

the parameter “nmi_watchdog=1” in /boot/grub/grub.conf file

• Disable SM sweep and Discovery Scan Time at switch level to avail CPU for

InfiniBand host management processes

• Collect the HCA and IB ports statistics dump for diagnosis purpose

# iba_capture .tgz

REFERENCES

• Oracle 10g RAC and SilverStorm’s RDS Installation Guide • Oracle 10g Performance and Deployment Guide • QuickSilver Fast Fabric User’s Guide

Oracle 10gR2 RAC on Linux Cluster using RDS over IB Interconnect Installation and Configuration December 2006

Author: Badrinath Tripathy

Contributing Author: Amit Das, Richard Frank, Roland Knapp, Daniel Dibbets Version 1.9

Oracle Corporation World Headquarters 500 Oracle Parkway

Redwood Shores, CA 94065 U.S.A.

Worldwide Inquiries:

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect

27

Phone: +1.650.506.7000 Fax: +1.650.506.7200 oracle.com

Copyright © 2006, Oracle. All rights reserved.

This document is provided for information purposes only and the contents hereof are subject to change without notice.

This document is not warranted to be error-free, nor subject to any other warranties or conditions, whether expressed orally or implied in law, including implied warranties and conditions of merchantability or fitness for a particular purpose. We specifically disclaim any

liability with respect to this document and no contractual obligations are formed either directly or indirectly by this document. This document may not be reproduced or transmitted in any form or by any means,

electronic or mechanical, for any purpose, without our prior written permission. Oracle, JD Edwards, PeopleSoft, and Siebel are registered trademarks of Oracle Corporation and/or its affiliates. Other names may be trademarks of their respective owners.

Oracle Real Application Clusters 10g Release 2: Installation and Configuration of Linux Clusters Using RDS over InfiniBand Interconnect