Global Field Instruments Price BookPage: ST-51

Effective Date: Oct 1, 2002

ST 3000 Series 900 Smart TransmitterIn-Line Gage Pressure (LGP)Model Selection Guide

Model Selection Guide34-ST-16-28 Issue 25Instructions Select the desired Key Number. The arrow to the right marks the selection available. Make one selection from each table, I and II, using the column below the proper arrow. Select as many Table III options as desired (if no options or approvals are desired, specify 9X). A (󰂊) denotes unrestricted availability. A letter denotes restricted availability. Restrictions follow Table IV.With Price Data

Honeywell Confidential & Proprietary

Key Number _ _ _ _ _ _ IIIIII (Optional)IVList Price equals the sum of all selections made.

- _ _ _- _ _ _ _ _-_ _, _ _ _ _+XXXXKEY NUMBERSpan0-20 to 0-500 psi/0-1.4 to 0-35 bar0-300 to 0-3000 psi/0-21 to 0-210 bar0-500 to 0-6000 psi/0-35 to 0-415 bar0-500 to 0-10000 psi/0-35 to 0-690 bar SelectionAvailabilityU.S.$9521,0561,0561,158

STG94LSTG97LSTG98LSTG99LGagePressureTABLE I - METER BODYMaterialof

ConstructionFill FluidProcess HeadConfiguration

WettedProcess Heads

Vent/DrainValves **

BarrierDiaphragms

316 St. St.316 St. St.SiliconeCTFE

1/2\" NPT (female)

----316 LSSHastelloy CE _ _F _ __ 1 __ 2 __ _ G

󰂊󰂊󰂊󰂊󰂊

0790520

TABLE IINo Selection

00000󰂊0

** Vent/Drains are Teflon coated for lubricity.

Industrial Measurement and Control, 16404 North Black Canyon Highway, Phoenix, AZ 85053

Printed in U.S.A. Copyright 2002 - Honeywell International Inc.

Global Field Instruments Price BookHoneywell Confidential & Proprietary

Page: ST-52

Effective Date: Oct 1, 2002

Availability

STG9 _ L47TABLE III - OPTIONSSelection8None00󰂊HART®Protocol Compatible ElectronicsHCyFOUNDATION Fieldbus CommunicationsFFrbAnalog Meter (0-100 Even 0-10 Square Root)ME󰂊Smart MeterSM󰂊bCustom Configuration of Smart MeterCImLocal ZeroLZxLocal Zero and SpanZSsbLightning ProtectionLP󰂊Custom Calibration and I.D. in MemoryCC󰂊Transmitter ConfigurationTC󰂊Write ProtectionWP󰂊Stainless Steel Customer Wired-On TagTG󰂊 (4 lines, 28 characters per line, customer supplied information)Stainless Steel Customer Wired-On Tag (blank)TB󰂊Mounting Bracket - Carbon SteelMB󰂊Mounting Bracket - ST. ST.SB󰂊bFlat Mounting Bracket - Carbon SteelFB󰂊316 ST.ST. Electronics Housing - with M20 Conduit ConnectionsSHn1/2\" NPT to M20 316SS Conduit Adapter (BASEEFA EEx d IIC)A1n1/2\" NPT to 3/4\" NPT 316 SS Conduit AdapterA2ubStainless Steel Housing with M20 to 1/2\" NPT 316 SS Conduit A3i Adapter (use for FM and CSA Approvals)Low Temperature - -50oC Ambient LimitLT󰂊Clean Transmitter for Oxygen or Chlorine Service with Certificate0XhOver-Pressure Leak Test with F3392 CertificateTP󰂊Calibration Test Report and Certificate of Conformance (F3399)F1󰂊Certificate of Conformance (F3391)F3󰂊bCertificate of Origin (F0195)F5󰂊FMEDA (SIL) CertificateF6󰂊NACE Certificate (F0198)F7󰂊Additional Warranty - 1 yearW1󰂊Additional Warranty - 2 yearsW2󰂊Additional Warranty - 3 yearsW3󰂊bAdditional Warranty - 4 yearsW4󰂊Table III continued next pageU.S.$04232115815825282859281717771769174284328478281982817777717334864

Honeywell Confidential & Proprietary

Global Field Instruments Price BookPage: ST-53

Effective Date: Oct 1, 2002

Availability

STG9 _ L47TABLE III - OPTIONS (continued)Selection8ApprovalBodyApproval TypeLocation or Classification No hazardous location approvals 9X󰂊Explosion ProofClass I, Div. 1, Groups A,B,C,DFactoryDust Ignition ProofClass II, III Div. 1, Groups E,F,GMutualNon-IncendiveClass I, Div. 2, Groups A,B,C,D1C󰂊Intrinsically SafeClass I, II, III, Div. 1, GroupsA,B,C,D,E,F,GExplosion ProofClass I, Div. 1, Groups B,C,DCSADust Ignition ProofClass II, III, Div. 1, Groups E,F,G2J󰂊bIntrinsically SafeClass I, II, III, Div. 1, GroupsA,B,C,D,E,F,GSAIntrinsically SafeEx ia IIC T44G󰂊(Australia)Non-SparkingEx n IIC T6 (T4 with SM option)Intrinsically Saft, ZoneEEx ia IIC T4, T5,T63S󰂊0/1 Flameproof, Zone 1EEx d IIC T5, T6, 3D󰂊ATEX*Enclosure IP 66/67Non-Sparking, Zone 2EEx nA, IIC T63N󰂊(Honeywell). Enclosure IP 66/67*See ATEX installation requirements in the ST 3000 User's Manual97/23/EC Pressure Equipment Directive (PED)

The ST 3000 pressure transmitters listed in this Model Selection Guide are in conformity with the essential requirements of the PED. A formal statement from TÜV Industry

Service Group of TÜV America, Inc., a division of TÜV Süddeutschland, a Notified Bodyregarding the Pressure Equipment Directive, is available upon request

TABLE IV

Factory IdentificationXXXX󰂊RESTRICTIONS

RestrictionAvailable Only With

Not Available With

LetterTable

SelectionTable

Selection

aApproval Body Pending

bSelect only one option from this group

hI_ 2 _

iIII1C or 2J

mIIISM

nIII1C, 2J

rIIITC, ME, 4G, 3S

sIII

FF, ME

uIIIF1D3, C1C3, 1C, 2J

xIIIFF, SM

yIII

4G

Note:

See ST-83 for Published Specials with pricing.See ST-89 and User's Manual for part numbers.

See ST-OE-9 for OMS Order Entry Information including TC, manuals,

certificates, drawings and SPINS.

See ST-OD-1 for tagging, ID, Transmitter Configuration (TC) and

calibration including factory default values.

To request a quotation for a non-published \"special\

Next Page Blank

U.S.$

0

0

0

0000

0Global Field Instruments Price BookPage: ST-54

Effective Date: Oct 1, 2002

Honeywell Confidential & Proprietary

This page is intentionally left blank.

因篇幅问题不能全部显示,请点此查看更多更全内容

Copyright © 2019- haog.cn 版权所有

违法及侵权请联系:TEL:199 1889 7713 E-MAIL:2724546146@qq.com

本站由北京市万商天勤律师事务所王兴未律师提供法律服务