您好,欢迎来到好走旅游网。
搜索
您的当前位置:首页管道油漆修补方案

管道油漆修补方案

来源:好走旅游网


Table of Content 目 录

一、 Project General Introduction工程概况 二、 References 编制依据 三、 Preparations 准备工作 四、 Painting Process 涂漆工艺

1、 Confirm the regions that need to repair and repair method 确认油漆损伤部位和修补方法

2、Surface Preparation Method表面处理方法 3、Painting涂漆

五、 Quality control and Inspection 质量控制及检查 六、 Safety 安全

七、 Paint Protection油漆保护

二 References 编制依据 三 Preparations 准备工作

1、The design and other technical document is ready; the construction drawing is reviewed.设计及其他技术文件齐全,施工图纸业经会审; 2、 Construction procedure and technical instructions are completed; The safety training and technical training from international company have been provided.完成施工方案和技术交底,进行了安全技术教育和国际公司技术培训;

3、 pipe and fittings shall have qualifications. 管段应具备出厂合格证;

4、 Material, tools, apparatus for test and inspection, construction facility and space are ready.材料,机具,检测仪器,施工设施及场地已齐备; 5、 Inspection must be done during the course of anticorrosion construction, and perform the acceptance immediately after anticorrosion is completed.防腐蚀工程施工过程中,必须进行中间检查;防腐蚀工程完工后,应立即进行验收; 6、 The coating shall have qualification from its manufacturer 油漆应有制造厂的质量证明书; 7、 Painting environmental condition shall be in accordance with the information on the product sheet. The surface temperature to be 30C.above dew point relative humidity shall be less than 85%. 涂装环境条件必须和产品说明书的信息一致。表面温度至少大于露点30C.。相对湿度最大植为85%。 8、 Selection of Paint 油漆选用

DC has provided the painting system suitable for this project. The selection of paint shall strictly follow DC construction painting system. Paint type, finish paint color and paint repair color should be chosen in accordance with the line list. The specific painting systems are as follows.

本项目DC已经给出了适合本项目的油漆系统,油漆选择严格按照DC油漆系统进行选择施工 。油漆种类、面漆和油漆修补的颜色按照line list规定选用,主要有如下种类。详细油漆系统对照表如下: Painting SystemDC201A 油漆系统DC201A

DC201A:new steelwork,piping and fabricated equipments,shop prepare(-20 to 1200C) DC201A Location 部位 Surface reparation Abrasive blast cleaning to ISO8501-1 Sa2.5, (Roughness 40-75 表面处理 microns)喷砂处理至 ISO8501-1 Sa2.5,粗糙度达到Rz=40-75 微米 Coating System 涂层配套 Coat Name Product Name DFT: microns干膜 涂层名称 产品名称 厚度:微米 Prime Coat Inorganic zinc-rich, Interzinc 22 Greenish grey, Matt 底漆 60-75 无机富锌底漆 Interzinc 22 绿灰色,平光 Mid-Coat MIO Epoxy Intergard475HS Gray 100-150 中间涂层 环氧MIO 中间漆 Intergard 475HS, 灰色 Top Coat Polyurethane color:meet Spec’s 面漆 requirements 60-75 聚氨酯面漆 颜色:符合规范要求 Typical Minimum/Maximum DFT Range 220-300 典型最小/最大干膜厚度范围 Pipe supports sand blasting, painting requirement should be the same as piping,. 管道支架的喷砂、涂漆与管道要求相同。

DC201B:Site work and repairs of steelworks,piping and fabricated equipments (-20 to 1200C) Location 部位 DC201B Surface preparation Abrasive blast cleaning to ISO8501-1 Sa2.5, (Roughness 40-75 表面处理 microns) 喷砂处理至 ISO8501-1 Sa2.5,粗糙度达到Rz=40-75 微米 Coating System 涂层配套 Coat Name Product Name DFT: microns 涂层名称 产品名称 干膜厚度:微米 Prime Coat Surface Tolerant Epoxy Intergard670HS 100-150 底漆 低表面处理环氧漆 Intergard670HS Mid-Coat Surface Tolerant Epoxy Intergard670HS 100-150 中间漆 低表面处理环氧漆 Intergard670HS Top-Coat Polyurethane color:meet spec”s 50-75 requirements 面漆 聚氨酯面漆 颜色:符合规范要求 Typical Minimum/Maximum DFT Range 250-375 典型最小/最大干膜厚度范围

DC202A:Galvanized surface,handrais(-5 to 600C).(can not use abrasive basting).

Location 部位 DC202 Surface preparation 清理基层表面油污到SSPC-SP1标准要求。 表面处理 Coating System 涂层配套 Coat Name Product Name DFT: microns 涂层名称 产品名称 干膜厚度:微米 Prime Coat 10-25 蚀刻底漆 Interprimer539 底漆 Mid-Coat 30-50 环氧底漆 Intergard269 中间漆 Top-Coat Polyurethane color: meet spec”s 50-75 requirements 面漆 聚氨酯面漆 颜色:符合规范要求 Typical Minimum/Maximum DFT Range 90-150 典型最小/最大干膜厚度范围

Painting SystemDC203 油漆系统DC203

DC203:steel piping and fabricated equipment under insulation (-30 to 1550C) Location 部位 Surface preparation 表面处理 DC203 Abrasive blast cleaning to ISO8501-1 Sa2.5, (Roughness 40-75 microns) 喷砂处理至 ISO8501-1 Sa2.5,粗糙度达到Rz=40-75 微米 Coating System 涂层配套 Coat Name Product Name DFT: microns 涂层名称 产品名称 干膜厚度:微米 Prime Coat Phonolic epoxy intertherm228 90-120 底漆 环氧酚醛高温漆 intertherm228 Top Coat Phonolic epoxy intertherm228 90-120 面漆 环氧酚醛高温漆 intertherm228 Typical Minimum/Maximum DFT Range 180-240 典型最小/最大干膜厚度范围 Painting System DC204 油漆系统DC204

steel piping and fabricated equipment under insulation (155 to 4000C) Location 部位 Surface preparation 表面处理 DC204 Abrasive blast cleaning to ISO8501-1 Sa2.5, (Roughness 40-75 microns)喷砂处理至 ISO8501-1 Sa2.5,粗糙度达到Rz=40-75 微米

Coating System 涂层配套 Coat Name Product Name 产品名称 涂层名称 Prime Coat Inorganic copolymer intertherm751CSA 底漆 冷喷铝高温漆 intertherm751CSA Top Coat Inorganic copolymer intertherm751CSA 面漆 冷喷铝高温漆 intertherm751CSA Typical Minimum/Maximum DFT Range 典型最小/最大干膜厚度范围 9 Main Equipment & Tools 主要机具 A、主要施工工具

Description机具名称 Wheel Grinding Machine砂轮磨光机 Manul blasting machine 手动喷砂机 Internal Grinding Machine内磨机 Power Blender动力搅拌机 Scraper刮刀 File锉刀 Wile Brush钢丝刷 Abrasive Cloth铁砂布 Paint Bucket油漆桶 Brush刷子 B、main inspection facility 主要检测工具 编号NO 1 Thermometer 温度计 Test temperature 检测温度 Sling psychrometer 手摇湿度计 3 Test temperature and humidity 检测温度和 湿度 Name 名称 Use 用途 Qty.数量 DFT: microns干膜 厚度:微米 90-120 90-120 180-240 As necessary按需 As necessary按需 As necessary按需 As necessary按需 As necessary按需 As necessary按需 Several若干 Several若干 As necessary按需 As necessary按需 Remarks 备注 -15~50℃, need to be calibrated termly 需定期校准 need to be calibrated termly 需定期校准 need to be calibrated termly 需定期校准 need to be calibrated termly 需定期校准 need to be calibrated termly 2 Dew point calculator Calculate dew point 计算露点 露点计算表 超生波测厚仪 Holiday tester 漏涂检测仪 测量涂层厚度 Check holidays of coatings 检测涂层漏涂点 4 5

6 7 Replicate tape profile tester 复膜 胶带法粗糙度检测仪 Tape for test cleaning 清洁度测试 胶带 需定期校准 Check the anchor profile of substrate 检测底材表面粗糙度 Cleaning test 检测清 洁度 8 9

Flash magnifier 放大 器 Knife 刀

四、 Painting Process 涂漆工艺

Local Area Touchup for Piping 管道局部损伤及焊缝修补工艺 1、 确认油漆损伤区域 Confirm damage regions need to repair

A、 Areas need to repair需要进行涂层修补的区域

Area of welding seam where welding has been done after painting and

unqualified local coating area caused by every kind of reason need to be repaired. Generally components shall be repaired include:

对于涂装后进行焊接的焊缝区域和各种原因造成的不合格局部涂层,应进行修补,一般情况下需要进行修补的构件为:

Welding seam area: area after construction coating finished. 焊缝区域:主要针对主要涂层已施工完毕的焊缝区域。

Damaged coating area: damaged by hot working transportation, lifting and loading etc. damaged local part of coating.

涂层损坏区域:由于热工作业和运输,吊装,装卸等原因造成的涂层损伤或损坏局部涂层部位。

Over thickness coating cause crack on inorganic zinc silicate coating.

Inspection with pachometer & record检查:漆膜测厚仪检测并记录 Finish Coat Touchup面漆修补 Intermediate Touchup needed)中间漆修补(若需) (If Confirm damaged positions and exact location of site weld 确认油漆损伤部位以及现场焊口的具体位置 Manual Surface preparation or sandblasted 表面手工处理及喷砂处理 Primer Touchup底漆修补

由于涂层厚度超厚,而导致无机硅酸锌涂层龟裂部位。

Local coating with defects: sagging, omission, pin hole caused by unsuitable construction.

有涂层缺陷的局部涂层:由于施工过程中施工不当造成的流挂,漏涂,针孔等局部涂层的位置。

Seriously polluted part of coating: Any contamination has already damaged coating (polluted by cement)or the local area where contamination can be removed by easy cleaning.

涂层被严重污染的部位:被污染物严重污染,污染物已造成涂层损坏(被水泥污染),或污染物已无法通过简单的清洗就能除去的局部涂层区域。

B、 Method of painting repair涂层修补的方法

For weld seam are or damaged area of coating: Use power sand paper disc to grind the weld seam area or damaged area of coating to Grade St3(damaged coating has been removed entirely ), the pipe welding joint will be treated by manual blasting machine by a level of Sa2.5.Damaged area and unbroken area shall have a overlapping slope. Overlapping area shall appear new and fresh surface of coating to enlarge bonding force between repair coating and raw coating. Repair position shall be cleaned adequately after preliminary surface treatment, then repair painting as per the whole set of painting repair system and arrive the designed film thickness. For small area, brush painting shall be used. But spray coating shall be used for mid-coating and final coating when more coating areas connected together. Brushing style will be taken to the touch up works to ensure the appearance of the coating.

对于焊缝区域或者涂层损坏区域:应用动力砂纸片将焊缝区域和涂层损坏区域打磨处理到St3级(被损坏的涂层应完全清除),管道焊口采用手持式喷砂机,除锈等级Sa2.5。损坏区域与完好区域涂层应的边缘部位应砂磨出搭接坡度,搭接区域的原涂层应砂磨漏出新鲜的涂层表面,以增加修补涂层与原涂层的结合力。修补位置基层表面处理结束后,应充分清洗该表面,然后按修补油漆配套系统进行涂层修补并达到设计要求的干膜厚度。油漆涂层修补采用刷涂,确保修补涂层的外观。 对于涂层缺陷,涂层龟裂,涂层污染的部位修补:先砂纸片,砂布或其他方法

清除缺陷涂层和严重污染涂层。然后按照对该部位涂层进行砂磨和清洗,并保证搭接涂层边缘一定的搭接坡度和新鲜的涂层表面。再按照修补涂层系统进行修补,涂层修补的其他要求同上节。

C、由于固化后的无机锌涂层很难进行自覆涂,因此,对于有缺陷和损坏的无机锌涂层应采用环氧富锌进行修补。 D、 被修补的涂层或基层表面应清洗干净,无污染物,如存在油污应充分清洗

油污(达到SSPC-SP1标准)。

E、 为确保修补涂层的外观,建议较大面积的涂层采用喷涂的方法施工。 注:

 检查管道外观,对所有在运输、倒运、现场焊接等过程中破坏的涂漆用记号

笔做好标记,并标记出打磨处理的范围。  确定现场焊口,未试压管段焊口以及不锈钢管的具体的位置。做好标记。 2、Surface Preparation 表面处理

Surface preparation before painting涂漆前的表面处理

 Surface preparation request: grade. St3, thorough rust removal by

hand or power machine or arrive Grade Sa2.5 by mechanical rust removal.

表面处理粗糙度要求: St3级 彻底的手工和动力工具除锈或者采用机械除锈达到Sa2.5级。

 Treatment by hand: Unwound scale, rust and aging coating on pipes

can be removed in using wire brush or rubber paper or manual machine or spade. 人工处理:管道表面上松散的氧化皮、锈蚀和老化涂层可用钢丝刷刷掉、砂皮纸砂去、用手工工具刮掉或铲除

 Power treatment: It’s better to use power machine than manual

machine when removing scale, rust or aging coating. But it can’t be used to remove the rust or scale attached to pipe surface firmly. Normally used power machine includes :wire brush, impulse tools, grinding machine and rubber sharpening machine. Pay more attention not to polish the metal surface, especially when using power wire brush, or it will destroy the required surface roughness. 动力处理:在清除松散的氧化皮、锈蚀和老化涂层时,用动力工具比用人工效果好,而且省力。但是动力工具不能除去紧紧附着在管道表面的锈蚀和氧化皮。通常采用的动力工具,包括钢丝刷、冲击工具、砂轮机及砂皮磨光机。但是必须注意,不要抛光金属表面,尤其是在使用动力钢丝刷时,否则会破坏涂覆所需的表面粗糙度。

 For cracked coats,grind the coat in the crack area comletely to reach

required roughness , and then commerce the repair paint work 。 对于龟裂的涂层,需将龟裂处涂层彻底打磨,并达到规定的粗糙度要求后再进行油漆的修补。  For cracked and slightly scratched coats,do not grind too hard 。

Only grind to the base coat for repairing with Interthane 990

top-coat 。对于轻微损伤的涂层,不需打磨过深,只需要适度打磨即可进行修补,可直接用Interthane 990 面漆。

 The repairing area should have 30—50mm adjoining area with the

pre-existing coat 。 The grinding should have some gradient to insure the repaired coat connects well with the pre-existing coat。修补区域与原有涂层有30—50mm 的搭接,要求打磨成一定的坡度,用于修补涂层与原有涂层平滑过渡。 3、Painting涂漆

➢ Painting must be done in a nice weather; doing in raining, fogging,

snowing and heavy dust is forbidden.涂料须选择在晴好天气的条件下施

工,在雨,雾,雪和较大灰尘的条件下禁止施工。

➢ Ensure the surface to be painted is clean. The surface can be cleaned

with dust collector or brush etc. The same treatment shall be done again after each film is dry. Then next coating can be applied.涂料表面必须保证清洁干净。涂漆前用吸尘器,刷子等清理干净,每层涂膜干燥后需经同样处理后,方可涂下一层涂料。 ➢ Ensure the seperation from other components around in the event that

any contamination occur prior to painting, and especially much attention to ground pretection shall be taken in case of any soil pollution. Separateing material can use tape (small range),color clothing and

wood board.

➢ 涂漆前必须对周围其它部件进行隔离以免造成周围部件的污染,特别注

意对地面的保护以免造成土壤的污染。隔离材料可采用胶带(小范围)、彩条布、木板等. ➢ The painting surface must be dry. The next paint can be applied only

when the last paint film is complete dry.涂漆表面必须干燥。前一道涂膜实干后,方可涂下一道漆。

不同温度条件下Interseal 670 HS 重涂间隔时间

Interseal 670 HS re-coat interval time under different temperatures

温度 temp. 10℃ 15℃

表干 Touch Dry 8小时 hrs 7小时 hrs 硬干 Hard Dry 32小时 hrs 26小时 hrs 自重涂间隔Re-coat by self 最小 Min. 32小时 hrs 26小时 hrs 最大 Max. 无 Extended 无 Extended

25℃ 40℃

5小时 hrs 2小时 hrs 18小时 hrs 6小时 hrs 18小时 hrs 6小时 hrs 无 Extended 无 Extended 不同温度条件下Interthane 990 表干、硬干和覆涂间隔时间:Touch dry , hard dry and re-coat interval time of Interthane 990 under different temperatures

温度 temp. 5℃ 15℃ 25℃ 40℃ 表干 Touch Dry 5小时 hrs 2.5小时 hrs 1.5小时 hrs 1小时 hrs 硬干 Hard Dry 24小时 hrs 10小时 hrs 6小时 hrs 3小时 hrs 自重涂间隔Re-coat by self 最小 Min. 24小时 hrs 10小时 hrs 6小时 hrs 3小时 hrs 最大 Max. 无 Extended 无 Extended 无 Extended 无 Extended 不同温度条件下Interzinc22重涂间隔时间 Surface Temp 温度计 Touch Dry 表干温度 Hard Dry 硬干时间 Over-coating interval with recommended top-coat 推荐面漆覆涂间隔时间 Minimum 最短时Maximum最长时间 间 50C 150C 250C 400C 30min 分钟 20min 分钟 10min 分钟 5min 分钟 3Hrs 小时 36-48Hrs 小时 90min 钟 60min 钟 30min 钟 分24-36Hrs 小时 分16-24Hrs 小时 分8-12Hrs 小时 Extended 无 Extended 无 Extended 无 Extended 无 不同温度条件下Intertherm228、Intergard475HS重涂间隔时间

Touch dry, Hard dry and Over-coating interval 表干,硬干,覆涂间隔时间: Surface Temp 温度计 Touch Dry 表干温度 Hard Dry 硬干时间 Over-coating interval with recommended top-coats 推荐面漆覆涂间隔时间 Minimum 最短时Maximum最长时间 间 50C

1.5 hrs 16Hrs 小16Hrs 小时 Extended 无限

时 150C 250C 1 hrs 1 hrs 10 hrs 5 hrs 10 Hrs 小时 5 Hrs 小时 制 Extended 无 Extended 无 Intertherm 228 and 751CSA layer application interval under different temperature conditions

不同温度条件下Intertherm228、Intertherm751CSA重涂间隔时间 Surface Temp 温度计 Touch Dry 表干温度 Hard Dry 硬干时间 Over-coating interval with recommended top-coat 推荐面漆覆涂间隔时间 Minimum 最短时Maximum最长时间 间 100C 150C 250C 400C

五 Quality control and Inspection 质量控制及检查 Doc. Clerk 资料员 Dispatcher 收发员 Materials Inspector 材料员 Quality Inspector 质检员 Construction Team Manager 施工队长 8 Hrs 小时 7Hrs 小时 5Hrs 小时 3Hrs 小时 16Hrs 小36Hrs 小时 时 12 Hrs 小24Hrs 小时 时 8 Hrs 小16Hrs 小时 时 6 Hrs 小16Hrs 小时 时 5 days 天 4 days 天 3 days 天 2 days 天 Project Manager 项目经理 QA/QC Manager 质检经理

6.2 Technical Requirement for Painting 油漆施工的技术要求

为保证涂装质量,油漆的调配必须由专人操作,严格依照说明书进行调配。

➢ The sort, color, film layer applied, thickness and the mark of the coating

shall be as per the design document.

涂料的种类,颜色,涂敷的层数、厚度和标记应符合设计文件的规定; ➢ Quality of coating shall according to following requirements:

涂层质量应符合下列要求:

a) Coating shall be uniform and with identical color.

涂层应均匀,颜色应一致;

b) Coating shall be integrity without damage and dripping.

涂层应完整,无损坏,流淌;

c) Film applied shall firmly adhere to and free of scale, wrinkle,

porosity, pinhole and other defects.

涂膜应附着牢固,无剥落,皱纹,气泡,针孔等缺陷;

d) The color ring shall be applied with uniform space and identical

width.

涂刷色环时,应间距均匀,宽度一致。

QC procedure:质量控制步骤:

1、Treatment of damaged surface of pipe: QC inspector and supervision

engineer shall inspect the damaged pipe surface after treatment.

Then the next final painting can be done. The time of final painting shall be controlled in 4 hours.管道损伤面的处理:管道损伤面处理后由质检员及监理工程师检查合格后才能进行下一步底漆的涂装。并控制在4小时之内完成底漆的涂装。

2、Painting choosing and ratio: It shall be done as per guideline of

manufacturer and manual strictly. Tag number of paint and process of mixing shall be traced by inspector. Control the mixing using life of paint.

油漆的选用及配比:油漆的选用及调配严格按照厂家的指导及说明书进行,质检员需对油漆的牌号及调配过程进行跟踪,并控制油漆的混合使用寿命。

3、The next painting shall only be done after the last painting finished and dried.

在上一层涂层完成后必须在涂层干硬后经行下道涂层的涂装。 4、Protection of painting position: Strictly prohibit other people to pollute

or damage and un-dried position of painting.

涂装部位的保护,严禁其他人员对未干部位的损坏及污染。

六、Safety 安全

➢ Obey the site regulations of Dow Corning. Apply for fire permit before grinding works. Apply for painting permit before painting work. 严格执行道康宁施工现场的管理要求,打磨工作前需办理动火作业许可,油漆涂装前办理油漆涂装工作许可。 ➢ The coating shall be stored in a special warehouse which has good

ventilation and be equipped with firefighting device; a warning plate “No Smoke/Fire”shall be set up; and no body is allowed to live in it. 涂料应在专门的仓库内储存,库房应通风良好,并应与配置消防器材,设置“严禁烟火”警示牌;库房内严禁住人。

➢ When enter into the painting site, all workers shall wear their badge,

safety helmat, safety shoes, goggles, gloves and other necessary protection articals.工作人员进入油漆现场必须整齐佩带胸卡、安全帽、安全鞋、防护眼镜、防护手套等必备防护用具。 ➢ The painting site must have good lighting, the temporary wiring shall be

safe and reliable and with good insulation.油漆现场必须有良好照明,临

时电器线路架设,要安全可靠,绝缘好。

➢ The sandblasting tank usd for sandblasting work shall receive hydro

test regularly, all pressure gauge, safety valve and etc. shall be calibrated regularly.喷砂作业用的喷砂罐应定期进行液压试验,所用的压力表安全阀等均应定期校验。 ➢ Painting in a confined space, it must have a good ventilation and with

designated personnel to watch. 在封闭空间内涂漆,必须保证良好的通

风,并有专人监护。

➢ All painters should wear special mask to prevent poisoning. 所有涂装

人员必须佩戴专用的口罩,以防油漆中毒。 ➢ Original scaffold will be used for the painting at height, if not , elevator

or ladder will be given instead as well as safety belt.

登高油漆工作尽量使用原有的脚手架作业,若无脚手架采用升降机或梯子并正确佩戴安全带。 ➢ Strictly apply to the elevator and ladder procedure.

严格遵守升降机及梯子的使用程序。

七、 油漆保护Paint Protection

Internatinal paint system is applied for steel structures, and the fabrication

work will be done in the workshop and later installed on site. Before entering into site, all ready products are done with primer, intermediate and finishing paint. Effective protection measures will be performed for the painting works.to decrease site touch-up。

本项目钢结构采用国际油漆系统,并且都在工厂预制现场安装。成品件进场前底漆、中间漆、面漆已经完成。现场的油漆保护做好有效的控制,才能减少现场油漆的修补。

Paint protection will be performed in three steps: 油漆保护可分为三部分进行跟踪:

First step: transportation and storage of the ready products 第一部分:成品件的运输及存放

➢ The ready products will be separated layer by layer with soft square

timbers during transportation.成品件运输时应用软质方木分层隔离。 ➢ Ready products will be laid on the square timber, no direct contact with

the ground is allowed.成品件储存应采用木方与地面隔离,严禁直接接触地面。 ➢ Special care should be taken during unloading of the ready products,

no throwing is allowed. 成品件到货卸车时应轻拿轻放,避免扔掷。 Second step: lifting and setting in position 第二部分:吊装及安装就位

➢ Use soft lifting belts during equipment lifting, cloth or rubber will be

used in between of the lifting belt and ready product to avoid paint

damages.吊装时选择软质吊装带,并在吊装带与成品件之间用布或胶皮隔离,以避免在吊装过程中损伤油漆。

➢ Hemp rope will be also used for directing the ready products during

lifting to avoid collision with outher structures or facilities.吊装时使用好遛绳,防止成品件与其它构件及设施发生碰撞。 ➢ No knocking with hard stuffs.严禁用硬物击打成品件。

➢ Protect the paint around welding seams when perform site welding

work with fire-proof cloth.现场焊接需注意焊缝四周的油漆的保护,可用防火布覆盖隔离。 Third step: protection after installation 第三部分:安装后的保护

➢ Daily inspection of the installed structures, take timely effective mesure

to stop or prevent the activities if found may cause paint damages.结构安装后应每天进行巡检,发现有破坏油漆的活动应及时提制止并采取有效措施加以防范。 ➢ Special care should be taken during setting up of the scaffolding to

avoid knocking and scratching of the painted parts. Effective anti-corrosion mesures should be applied for the scaffolding materials.脚手架搭设过程中特别注意对油漆的保护避免碰撞及摩擦,且脚手架材料已经做好有效防腐。 ➢ Protect the ready painted products from being polluted by the splashing

materials fromg site grinding work.各专业在现场实施打磨工作时,打磨飞溅严禁对准成品件以免造成污染。 ➢ Fire-proof cloth should be used for protection during welding to avoid

being polluted by the falling welding dregs.焊接时用防火布等做好隔离防护,防止焊渣落到下方成品件上造成污染。 ➢ It is not allowed to scrabble on the ready products.

注意对成品的保护。